nanoFramework.Iot.Device.Tsl256x 1.2.601

Prefix Reserved
There is a newer version of this package available.
See the version list below for details.
dotnet add package nanoFramework.Iot.Device.Tsl256x --version 1.2.601                
NuGet\Install-Package nanoFramework.Iot.Device.Tsl256x -Version 1.2.601                
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="nanoFramework.Iot.Device.Tsl256x" Version="1.2.601" />                
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add nanoFramework.Iot.Device.Tsl256x --version 1.2.601                
#r "nuget: nanoFramework.Iot.Device.Tsl256x, 1.2.601"                
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install nanoFramework.Iot.Device.Tsl256x as a Cake Addin
#addin nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.601

// Install nanoFramework.Iot.Device.Tsl256x as a Cake Tool
#tool nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.601                

TSL256x/TSL2560/TSL2561 - Illuminance sensor

TSL2560 and TSL2561 are illuminance sensor. They are light-to-digital converters that transform light intensity to a digital signal output capable of direct I2C (TSL2561) or SMBus (TSL2560) interface. Each device combines one broadband photodiode (visible plus infrared) and one infrared-responding photodiode on a single CMOS integrated circuit capable of providing a near-photopic response over an effective 20-bit dynamic range (16-bit resolution).

Two integrating ADCs convert the photodiode currents to a digital output that represents the irradiance measured on each channel. This digital output can be input to a microprocessor where illuminance (ambient light level) in lux is derived using an empirical formula to approximate the human eye response.

The TSL2560 device permits an SMB-Alert style interrupt, and the TSL2561 device supports a traditional level style interrupt that remains asserted until the firmware clears it.

Documentation

Board

image

Usage

Basic usage

TSL2560 and TSL2561 are designed to have an integration time and a gain for measuring the 2 ADC. The defaults are 402 milliseconds and a normal gain of x1.

The basic usage is the following:

I2cDevice i2cDevice = I2cDevice.Create(new I2cConnectionSettings(1, Tsl256x.DefaultI2cAddress));
Tsl256x tsl256X = new(i2cDevice, PackageType.Other);
tsl256X.IntegrationTime = IntegrationTime.Integration402Milliseconds;
tsl256X.Gain = Gain.Normal;
var lux = tsl256X.MeasureAndGetIlluminance();
Console.WriteLine($"Illuminance is {lux.Lux} Lux");

notes:

  • Be aware, there are 2 types of packaging the CS and the Others T, FN and CL. Refer to the documentation to understand which package you have on the board. This is an argument when creating the sensor as the calculation for the illuminance is different.
  • There are 3 different possible I2C addresses for this device depending on how the address pin is setup:
    • DefaultI2cAddress = 0x39: When address pin is to the ground
    • SecondI2cAddress = 0x29: When address pin is floating
    • ThirdI2cAddress = 0x49: When address pin is to VDD

Check the version

You can determine if you have a TSL2560 or TSL2561 version:

var ver = tsl256X.Version;
string msg = ver.Major & 0x01 == 0x01 ? $"This is a TSL2561, version {ver}" : $"This is a TSL2560, version {ver}";
Console.WriteLine(msg);

Using interruptions

You can set interruptions, you have different possible ones you can set thru the InterruptLevel:

  • OutputDisabled: will disable the interrupt
  • LevelInterrupt: will use the permanent interrupt you'll setup, see right after
  • SmbAlertCompliant: will send an alert on the SMB bus (version TSL2560 only) on address 0b0000_1100
  • TestMode: will generate an interruption for test purpose

The InterruptPersistence will allow you to select a specific timing for the interrupt:

  • EveryAdc: each time you have a measurement
  • AnyValueOutsideThreshold: any time a value will be outside of the setup threshold
  • OutOfRangeXXIntegrationTimePeriods: where XX is from 2 to 15, will interrupt only if the value remains outside more than XX times

The following example shows how to setup a basic interruption using test mode:

Console.WriteLine("Set interruption to test. Read the interrupt pin");
GpioController controller = new();
controller.OpenPin(PinInterrupt, PinMode.Input);
tsl256X.InterruptControl = InterruptControl.TestMode;
tsl256X.Enabled = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ushort ch0, out ushort ch1);

You can setup interruptions on thresholds as well. You first need to setup a threshold and then the type of interruptions.

// Adjust those values with a previous measurement to understand the conditions, find a level where then you can
// hide the sensor with your arm and make it going under the minimum level or vice versa with a lamp
tsl256X.SetThreshold(0x0000, 0x00FF);
tsl256X.InterruptPersistence = InterruptPersistence.OutOfRange06IntegrationTimePeriods;
tsl256X.InterruptControl = InterruptControl.LevelInterrupt;
tsl256X.Power = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");

Manual integration

You can set a manual integration as well. Be aware that you won't be able to easily calculate an illuminance equivalent. You need to use the manual integration functions offered:

Console.WriteLine("This will use a manual integration for 2 seconds");
tsl256X.StartManualIntegration();
Thread.Sleep(2000);
tsl256X.StopManualIntegration();
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");
Product Compatible and additional computed target framework versions.
.NET Framework net is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last updated
1.2.673 62 10/23/2024
1.2.656 80 10/3/2024
1.2.639 113 9/6/2024
1.2.631 92 8/28/2024
1.2.613 104 8/9/2024
1.2.601 69 7/26/2024
1.2.590 86 7/17/2024
1.2.573 109 6/19/2024
1.2.570 106 6/14/2024
1.2.536 113 4/15/2024
1.2.534 113 4/13/2024
1.2.514 114 3/22/2024
1.2.494 110 2/28/2024
1.2.462 195 1/5/2024
1.2.458 124 12/20/2023
1.2.436 167 11/10/2023
1.2.416 104 11/8/2023
1.2.403 144 10/6/2023
1.2.396 145 9/27/2023
1.2.384 144 9/6/2023
1.2.378 158 8/16/2023
1.2.369 159 8/2/2023
1.2.363 151 7/28/2023
1.2.357 162 7/19/2023
1.2.354 167 7/14/2023
1.2.345 154 6/21/2023
1.2.341 158 6/14/2023
1.2.337 175 6/7/2023
1.2.335 164 6/2/2023
1.2.329 161 5/26/2023
1.2.316 167 5/16/2023
1.2.313 170 5/12/2023
1.2.302 174 5/10/2023
1.2.297 154 5/3/2023
1.2.273 259 3/17/2023
1.2.267 266 3/10/2023
1.2.263 247 3/8/2023
1.2.259 273 2/27/2023
1.2.256 280 2/24/2023
1.2.253 272 2/22/2023
1.2.222 316 1/9/2023
1.2.217 314 1/6/2023
1.2.212 305 1/5/2023
1.2.208 331 1/3/2023
1.2.203 324 12/28/2022
1.2.159 390 11/14/2022
1.2.153 378 11/5/2022
1.2.141 411 10/25/2022
1.2.128 406 10/22/2022
1.2.125 419 10/12/2022
1.2.87 518 9/15/2022
1.2.63 426 9/3/2022
1.2.47 441 8/15/2022
1.2.40 438 8/6/2022
1.2.38 440 8/5/2022
1.2.28 418 8/1/2022
1.2.13 452 7/24/2022
1.2.10 441 7/23/2022
1.1.142.3202 476 7/7/2022
1.1.133.52556 455 6/30/2022
1.1.121.35854 464 6/26/2022
1.1.118.19693 461 6/24/2022
1.1.116.8772 451 6/24/2022
1.1.102.51394 433 6/15/2022
1.1.99.36719 434 6/14/2022
1.1.97.17326 452 6/13/2022
1.1.92.53000 444 6/8/2022
1.1.72.29765 450 5/31/2022
1.1.61.27737 459 5/25/2022
1.1.58.10097 458 5/23/2022
1.1.54.28879 447 5/23/2022
1.1.40 470 5/5/2022
1.1.3 454 4/15/2022
1.1.1 474 4/14/2022
1.0.300 462 4/3/2022
1.0.288-preview.113 126 3/25/2022
1.0.288-preview.107 115 3/24/2022
1.0.288-preview.104 111 3/22/2022
1.0.288-preview.103 114 3/21/2022
1.0.288-preview.99 121 3/18/2022
1.0.288-preview.94 125 3/15/2022
1.0.288-preview.77 122 2/27/2022
1.0.288-preview.75 115 2/26/2022
1.0.288-preview.63 121 2/16/2022
1.0.288-preview.61 119 2/12/2022
1.0.288-preview.58 119 2/10/2022
1.0.288-preview.53 124 2/9/2022
1.0.288-preview.48 135 2/4/2022
1.0.288-preview.41 135 1/31/2022
1.0.288-preview.22 125 1/27/2022
1.0.288-preview.20 136 1/27/2022
1.0.288-preview.18 139 1/27/2022
1.0.272 487 1/10/2022
1.0.260 328 12/10/2021
1.0.259 330 12/9/2021
1.0.258 316 12/7/2021
1.0.231 341 10/27/2021