nanoFramework.Iot.Device.Dhtxx 1.2.573

Prefix Reserved
There is a newer version of this package available.
See the version list below for details.
dotnet add package nanoFramework.Iot.Device.Dhtxx --version 1.2.573                
NuGet\Install-Package nanoFramework.Iot.Device.Dhtxx -Version 1.2.573                
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="nanoFramework.Iot.Device.Dhtxx" Version="1.2.573" />                
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add nanoFramework.Iot.Device.Dhtxx --version 1.2.573                
#r "nuget: nanoFramework.Iot.Device.Dhtxx, 1.2.573"                
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install nanoFramework.Iot.Device.Dhtxx as a Cake Addin
#addin nuget:?package=nanoFramework.Iot.Device.Dhtxx&version=1.2.573

// Install nanoFramework.Iot.Device.Dhtxx as a Cake Tool
#tool nuget:?package=nanoFramework.Iot.Device.Dhtxx&version=1.2.573                

DHT10/DHT11/DHT12/DHT21/DHT22 - Digital-Output Relative Humidity & Temperature Sensor Module

IMPORTANT This sensor is very time sensitive. This implementation will only work on few boards. Do not use with ESP32. If you are working with an ESP32, to use any of the DHT with 1 wire protocol, please use the Dhtxx.Esp32 version.

The DHT temperature and humidity sensors are very popular. This projects support DHT10, DHT11, DHT12, DHT21(AM2301), DHT22(AM2302).

Documentation

DHT10 DHT11 DHT12 DHT21 DHT22
Image dht10 dht11 dht12 dht21 dht22
Temperature Range -40 ~ 80 ℃ 0 ~ 60 ℃ -20 ~ 60 ℃ -40 ~ 80 ℃ -40 ~ 80 ℃
Humidity Range 0 ~ 99.9 % 2 ~ 95 % 20 ~ 95 % 0 ~ 99.9 % 0 ~ 99.9 %
Temperature Accuracy ±0.5 ℃ ±2 ℃ ±0.5 ℃ ±0.5 ℃ ±0.5 ℃
Humidity Accuracy ±3 % ±5 % ±4 % ±3 % ±2 %
Protocol I2C 1-Wire I2C, 1-Wire 1-Wire 1-Wire

Usage

1-Wire Protocol

// GPIO Pin
using (Dht11 dht = new Dht11(26))
{
    var temperature = dht.Temperature;
    var humidity = dht.Humidity;
    // You can only display temperature and humidity if the read is successful otherwise, this will raise an exception as
    // both temperature and humidity are NAN
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {temperature.DegreesCelsius} \u00B0C, Humidity: {humidity.Percent} %");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(temperature, humidity).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(temperature, humidity).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Note: On the RPi with any of the DHT sensor, 1-Wire works using Raspian but not with Windows 10 IoT Core. The device has to switch the 1-wire pin between input and output and vice versa. It seems that Windows IoT Core OS can't switch the pin direction quick enough. There have been suggestions for using two pins; one for input and one for output. This solution has not been implemented here, but these are some handy links that may help setting that up:

I2C Protocol

Important: make sure you properly setup the I2C pins especially for ESP32 before creating the I2cDevice, make sure you install the nanoFramework.Hardware.ESP32 nuget:

//////////////////////////////////////////////////////////////////////
// when connecting to an ESP32 device, need to configure the I2C GPIOs
// used for the bus
Configuration.SetPinFunction(21, DeviceFunction.I2C1_DATA);
Configuration.SetPinFunction(22, DeviceFunction.I2C1_CLOCK);

For other devices like STM32, please make sure you're using the preset pins for the I2C bus you want to use.

Only DHT12 can use I2C protocol.

I2cConnectionSettings settings = new I2cConnectionSettings(1, DhtSensor.DefaultI2cAddressDht12);
I2cDevice device = I2cDevice.Create(settings);

using (Dht12 dht = new Dht12(device))
{
    var tempValue = dht.Temperature;
    var humValue = dht.Humidity;
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {tempValue.Celsius:0.#}\u00B0C");
        Debug.WriteLine($"Relative humidity: {humValue:0.#}%");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(tempValue, humValue).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(tempValue, humValue).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Reading frequency and quality measurement

In the case of I2C or GPIO, any type of DHT needs a bit of time between 2 readings. DHT22 documentation refer to a sensing period of 2 seconds and a collecting period higher than 1.7 seconds. Measuring with higher frequency won't give you more accurate numbers. As you can see from the specifications, the accuracy depends on the sensor type, it goes from ±2 ℃ for the DHT11 to ±0.5 ℃ for the others. Even if the parity check can come clear, we do recommend to check that the data are in a normal range. For example of humidity is higher than 100%, then it means that measurement is wrong. This check has not been done in the binding itself, so you may consider adding a check on your application side.

The DHT sensors are very sensitive, avoid too long cables, electromagnetic perturbations and compile the code as release not debug to increase the quality of measurement.

FAQ

I always get wrong measurements, what's happening?

Please check that the sensor is plugged correctly, make sure you are using the correct pin.

Please check you are using the correct sensor, only DHT10 and DHT12 supports I2C. All others support only GPIO with 1 wire protocol. DHT12 supports both.

The data I measure are not correct, humidity seems ok but temperature is always weird, what's the problem?

Please check you are using the correct sensor. Refer to the top part of this page to check which sensor you have. Using a DHT11 instead of a DHT22 will give you a wrong temperature.

I am trying to get a temperature and humidity 5 times per seconds but I mainly get wrong measurements, why?

This is absolutely normal, you should check the measurements once every 2 seconds approximately. Don't try to get more measures than once every 2 seconds.

When reading the temperature and humidity and trying to write the data in the console, I get an exception, why?

You need to check first if the measurement has been successful. If the measurement hasn't been successful, the default values will be NaN and so you won't be able to convert the temperature or humidity and you'll get an exception. This is the correct way of first reading the sensor and then checking the reading was correct and finally using the temperature and humidity data:

var tempValue = dht.Temperature;
var humValue = dht.Humidity;
if (dht.IsLastReadSuccessful)
{
    Debug.WriteLine($"Temperature: {tempValue.Celsius:0.#}\u00B0C");
    Debug.WriteLine($"Relative humidity: {humValue:0.#}%");
}

I have a Raspberry Pi 4 and I get an exception when creating the DHT sensor

See this issue 1145. We're actively trying to fix it automatically. You will have to force using either the Raspberry Pi 3 driver, either the LibGpiodDriver. This is how you can force using a specific drive, in this case the Raspberry Pi 3 one which will work:

GpioDriver driver = new RaspberryPi3Driver();
var controller = new GpioController(PinNumberingScheme.Logical, driver);
// This uses pin 4 in the logical schema so pin 7 in the physical schema
var dht = new Dht11(4, gpioController: controller);

My DHT sensor using 1 wire protocol is not working on my Raspberry Pi with Windows 10 IoT Core, what can I do?

On the RPi with any of the DHT sensor, 1-Wire works using Raspian but not with Windows 10 IoT Core. The device has to switch the 1-wire pin between input and output and vice versa. It seems that Windows IoT Core OS can't switch the pin direction quick enough. There have been suggestions for using two pins; one for input and one for output. This solution has not been implemented here, but these are some handy links that may help setting that up:_

Now if your sensor is an I2C sensor, it should just work perfectly on Windows 10 IoT Core.

Example of DHTxx

Hardware Required

  • DHT10/DHT11/DHT12/DHT21/DHT22
  • Male/Female Jumper Wires

Circuit

1-Wire Protocol Circuit

Simply connect your DHTxx data pin to GPIO26 (physical pin 37), the ground to the ground (physical pin 6) and the VCC to +5V (physical pin 2).

schema

Some sensors are already sold with the 10K resistor. Connect the GPIO26 to the data pin, its position can vary depending on the integrator.

I2C Protocol Circuit

schematics

  • SCL - SCL
  • SDA - SDA
  • VCC - 5V
  • GND - GND

Code

// GPIO Pin
using (Dht11 dht = new Dht11(26))
{
    var temperature = dht.Temperature;
    var humidity = dht.Humidity;
    // You can only display temperature and humidity if the read is successful otherwise, this will raise an exception as
    // both temperature and humidity are NAN
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {temperature.DegreesCelsius} \u00B0C, Humidity: {humidity.Percent} %");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(temperature, humidity).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(temperature, humidity).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Sample application navigation

This sample application allows you to select either a DHT10 through I2C either any other supported DHT through GPIO:

Select the DHT sensor you want to use:
 1. DHT10 on I2C
 2. DHT11 on GPIO
 3. DHT12 on GPIO
 4. DHT21 on GPIO
 5. DHT22 on GPIO

Just select the sensor you want to test and use by typing the number. For example, if you want to test a DHT22, type 5.

Then, you are prompted to type the pin number in the logical schema:

Which pin do you want to use in the logical pin schema?

If you want to use the pin 26, then type 26 and enter. This will then create a DHT22 sensor attached to pin 26 and start the measurement.

Please note that the few first measurements won't be correct, that's totally normal and related to the fact the sensor needs a bit of time to warm up and give data. Those sensors are very sensitive and too long wires, many perturbations, code compile as debug will increase the numbers of bad readings.

Result

dht22 output

Note: reading this sensor is sensitive, if you can't read anything, make sure you have it correctly cabled. Also note you'll get better results when running in Release mode.

Product Compatible and additional computed target framework versions.
.NET Framework net is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last updated
1.2.673 77 10/23/2024
1.2.662 77 10/11/2024
1.2.656 74 10/3/2024
1.2.639 102 9/6/2024
1.2.631 98 8/28/2024
1.2.613 106 8/9/2024
1.2.601 81 7/26/2024
1.2.590 95 7/17/2024
1.2.573 108 6/19/2024
1.2.570 101 6/14/2024
1.2.560 114 5/29/2024
1.2.548 128 5/15/2024
1.2.536 115 4/15/2024
1.2.514 122 3/22/2024
1.2.494 112 2/28/2024
1.2.474 128 1/24/2024
1.2.462 141 1/5/2024
1.2.458 130 12/20/2023
1.2.436 182 11/10/2023
1.2.416 117 11/8/2023
1.2.403 147 10/6/2023
1.2.396 128 9/27/2023
1.2.384 147 9/6/2023
1.2.378 132 8/16/2023
1.2.369 168 8/2/2023
1.2.363 149 7/28/2023
1.2.357 157 7/19/2023
1.2.354 153 7/14/2023
1.2.345 154 6/21/2023
1.2.341 127 6/14/2023
1.2.337 150 6/7/2023
1.2.335 157 6/2/2023
1.2.329 145 5/26/2023
1.2.316 152 5/16/2023
1.2.313 148 5/12/2023
1.2.302 130 5/10/2023
1.2.297 150 5/3/2023
1.2.273 284 3/17/2023
1.2.267 223 3/10/2023
1.2.263 246 3/8/2023
1.2.259 259 2/27/2023
1.2.256 238 2/24/2023
1.2.253 252 2/22/2023
1.2.222 340 1/9/2023
1.2.217 331 1/6/2023
1.2.208 307 1/3/2023
1.2.203 314 12/28/2022
1.2.159 385 11/14/2022
1.2.153 375 11/5/2022
1.2.141 403 10/25/2022
1.2.128 390 10/22/2022
1.2.122 447 10/12/2022
1.2.114 434 10/8/2022
1.2.95 451 9/22/2022
1.2.87 536 9/15/2022
1.2.73 438 9/8/2022
1.2.63 433 9/3/2022
1.2.47 470 8/15/2022
1.2.40 463 8/6/2022
1.2.38 445 8/5/2022
1.2.28 442 8/1/2022
1.2.13 464 7/24/2022
1.2.10 465 7/23/2022
1.1.142.3202 481 7/7/2022
1.1.133.52556 457 6/30/2022
1.1.121.35854 451 6/26/2022
1.1.116.8772 451 6/24/2022
1.1.113.2032 451 6/23/2022
1.1.102.51394 462 6/15/2022
1.1.99.36719 434 6/14/2022
1.1.72.29765 432 5/31/2022
1.1.64.21380 450 5/26/2022
1.1.58.10097 471 5/23/2022
1.1.54.28879 466 5/23/2022
1.1.40 505 5/5/2022
1.1.3 505 4/15/2022
1.1.1 462 4/14/2022
1.0.300 451 3/31/2022
1.0.288-preview.114 129 3/25/2022
1.0.288-preview.113 116 3/25/2022
1.0.288-preview.103 106 3/21/2022
1.0.288-preview.100 119 3/19/2022
1.0.288-preview.99 123 3/18/2022
1.0.288-preview.98 115 3/18/2022
1.0.288-preview.94 123 3/15/2022
1.0.288-preview.93 118 3/15/2022
1.0.288-preview.87 121 3/10/2022
1.0.288-preview.86 119 3/8/2022
1.0.288-preview.77 121 2/27/2022
1.0.288-preview.75 114 2/26/2022
1.0.288-preview.65 121 2/18/2022
1.0.288-preview.63 118 2/16/2022
1.0.288-preview.61 121 2/12/2022
1.0.288-preview.58 115 2/10/2022
1.0.288-preview.53 109 2/9/2022
1.0.288-preview.48 138 2/4/2022
1.0.288-preview.41 131 1/31/2022
1.0.288-preview.29 127 1/28/2022
1.0.288-preview.20 141 1/27/2022
1.0.288-preview.19 141 1/27/2022
1.0.288-preview.18 129 1/27/2022
1.0.288-preview.5 134 1/24/2022
1.0.288-preview.3 122 1/21/2022
1.0.288-preview.1 130 1/21/2022
1.0.272 175 1/10/2022
1.0.261 327 12/22/2021
1.0.259 325 12/9/2021
1.0.258 325 12/7/2021
1.0.155 380 8/31/2021
1.0.143 244 7/21/2021
1.0.91 189 5/27/2021