nanoFramework.Iot.Device.Dhtxx.Esp32 1.2.297

Prefix Reserved
There is a newer version of this package available.
See the version list below for details.
dotnet add package nanoFramework.Iot.Device.Dhtxx.Esp32 --version 1.2.297                
NuGet\Install-Package nanoFramework.Iot.Device.Dhtxx.Esp32 -Version 1.2.297                
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="nanoFramework.Iot.Device.Dhtxx.Esp32" Version="1.2.297" />                
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add nanoFramework.Iot.Device.Dhtxx.Esp32 --version 1.2.297                
#r "nuget: nanoFramework.Iot.Device.Dhtxx.Esp32, 1.2.297"                
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install nanoFramework.Iot.Device.Dhtxx.Esp32 as a Cake Addin
#addin nuget:?package=nanoFramework.Iot.Device.Dhtxx.Esp32&version=1.2.297

// Install nanoFramework.Iot.Device.Dhtxx.Esp32 as a Cake Tool
#tool nuget:?package=nanoFramework.Iot.Device.Dhtxx.Esp32&version=1.2.297                

DHTxx.Esp32 - Digital-Output Relative Humidity & Temperature Sensor Module

IMPORTANT This implementation will only work on with ESP32. Don't use this implementation for those MCU. This implementation requires 2 pins. One is used to write to the sensor and the other is used to read the data using RMT.

The DHT temperature and humidity sensors are very popular. This projects support DHT10, DHT11, DHT12, DHT21(AM2301), DHT22(AM2302).

Documentation

DHT10 DHT11 DHT12 DHT21 DHT22
Image dht10 dht11 dht12 dht21 dht22
Temperature Range -40 ~ 80 ℃ 0 ~ 60 ℃ -20 ~ 60 ℃ -40 ~ 80 ℃ -40 ~ 80 ℃
Humidity Range 0 ~ 99.9 % 2 ~ 95 % 20 ~ 95 % 0 ~ 99.9 % 0 ~ 99.9 %
Temperature Accuracy ±0.5 ℃ ±2 ℃ ±0.5 ℃ ±0.5 ℃ ±0.5 ℃
Humidity Accuracy ±3 % ±5 % ±4 % ±3 % ±2 %
Protocol I2C 1-Wire I2C, 1-Wire 1-Wire 1-Wire

Usage

1-Wire Protocol

// GPIO Pin
using (Dht11 dht = new Dht11(12, 24))
{
    var temperature = dht.Temperature;
    var humidity = dht.Humidity;
    // You can only display temperature and humidity if the read is successful otherwise, this will raise an exception as
    // both temperature and humidity are NAN
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {temperature.DegreesCelsius} \u00B0C, Humidity: {humidity.Percent} %");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(temperature, humidity).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(temperature, humidity).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Note: On the RPi with any of the DHT sensor, 1-Wire works using Raspian but not with Windows 10 IoT Core. The device has to switch the 1-wire pin between input and output and vice versa. It seems that Windows IoT Core OS can't switch the pin direction quick enough. There have been suggestions for using two pins; one for input and one for output. This solution has not been implemented here, but these are some handy links that may help setting that up:

I2C Protocol

Important: make sure you properly setup the I2C pins especially for ESP32 before creating the I2cDevice, make sure you install the nanoFramework.Hardware.ESP32 nuget:

//////////////////////////////////////////////////////////////////////
// when connecting to an ESP32 device, need to configure the I2C GPIOs
// used for the bus
Configuration.SetPinFunction(21, DeviceFunction.I2C1_DATA);
Configuration.SetPinFunction(22, DeviceFunction.I2C1_CLOCK);

For other devices like STM32, please make sure you're using the preset pins for the I2C bus you want to use.

Only DHT12 can use I2C protocol.

I2cConnectionSettings settings = new I2cConnectionSettings(1, DhtSensor.DefaultI2cAddressDht12);
I2cDevice device = I2cDevice.Create(settings);

using (Dht12 dht = new Dht12(device))
{
    var tempValue = dht.Temperature;
    var humValue = dht.Humidity;
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {tempValue.Celsius:0.#}\u00B0C");
        Debug.WriteLine($"Relative humidity: {humValue:0.#}%");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(tempValue, humValue).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(tempValue, humValue).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Reading frequency and quality measurement

In the case of I2C or GPIO, any type of DHT needs a bit of time between 2 readings. DHT22 documentation refer to a sensing period of 2 seconds and a collecting period higher than 1.7 seconds. Measuring with higher frequency won't give you more accurate numbers. As you can see from the specifications, the accuracy depends on the sensor type, it goes from ±2 ℃ for the DHT11 to ±0.5 ℃ for the others. Even if the parity check can come clear, we do recommend to check that the data are in a normal range. For example of humidity is higher than 100%, then it means that measurement is wrong. This check has not been done in the binding itself, so you may consider adding a check on your application side.

The DHT sensors are very sensitive, avoid too long cables, electromagnetic perturbations and compile the code as release not debug to increase the quality of measurement.

FAQ

I always get wrong measurements, what's happening?

Please check that the sensor is plugged correctly, make sure you are using the correct pin.

Please check you are using the correct sensor, only DHT10 and DHT12 supports I2C. All others support only GPIO with 1 wire protocol. DHT12 supports both.

The data I measure are not correct, humidity seems ok but temperature is always weird, what's the problem?

Please check you are using the correct sensor. Refer to the top part of this page to check which sensor you have. Using a DHT11 instead of a DHT22 will give you a wrong temperature.

I am trying to get a temperature and humidity 5 times per seconds but I mainly get wrong measurements, why?

This is absolutely normal, you should check the measurements once every 2 seconds approximately. Don't try to get more measures than once every 2 seconds.

When reading the temperature and humidity and trying to write the data in the console, I get an exception, why?

You need to check first if the measurement has been successful. If the measurement hasn't been successful, the default values will be NaN and so you won't be able to convert the temperature or humidity and you'll get an exception. This is the correct way of first reading the sensor and then checking the reading was correct and finally using the temperature and humidity data:

var tempValue = dht.Temperature;
var humValue = dht.Humidity;
if (dht.IsLastReadSuccessful)
{
    Debug.WriteLine($"Temperature: {tempValue.Celsius:0.#}\u00B0C");
    Debug.WriteLine($"Relative humidity: {humValue:0.#}%");
}

Example of DHTxx

Hardware Required

  • DHT10/DHT11/DHT12/DHT21/DHT22
  • Male/Female Jumper Wires

Circuit

1-Wire Protocol Circuit

Simply connect your DHTxx data pin to GPIO12 and GPIO14, the ground to the ground and the VCC to +3.3V.

schema

Some sensors are already sold with the 10K resistor. Connect the both GPIO12 and GPIO14 to the data pin, its position can vary depending on the integrator.

I2C Protocol Circuit

schematics

  • SCL - SCL
  • SDA - SDA
  • VCC - 5V
  • GND - GND

Code

// GPIO Pin
using (Dht11 dht = new Dht11(26))
{
    var temperature = dht.Temperature;
    var humidity = dht.Humidity;
    // You can only display temperature and humidity if the read is successful otherwise, this will raise an exception as
    // both temperature and humidity are NAN
    if (dht.IsLastReadSuccessful)
    {
        Debug.WriteLine($"Temperature: {temperature.DegreesCelsius} \u00B0C, Humidity: {humidity.Percent} %");

        // WeatherHelper supports more calculations, such as saturated vapor pressure, actual vapor pressure and absolute humidity.
        Debug.WriteLine(
            $"Heat index: {WeatherHelper.CalculateHeatIndex(temperature, humidity).Celsius:0.#}\u00B0C");
        Debug.WriteLine(
            $"Dew point: {WeatherHelper.CalculateDewPoint(temperature, humidity).Celsius:0.#}\u00B0C");
    }
    else
    {
        Debug.WriteLine("Error reading DHT sensor");
    }
}

Sample application navigation

This sample application allows you to select either a DHT10 through I2C either any other supported DHT through GPIO:

Select the DHT sensor you want to use:
 1. DHT10 on I2C
 2. DHT11 on GPIO
 3. DHT12 on GPIO
 4. DHT21 on GPIO
 5. DHT22 on GPIO

Just adjust the device variable. For example, if you want to test a DHT22, adjust it to 5.

// Set these values to test according to the list below:
var pinEcho = 12;
var pinTrigger = 14;
var device = 5;

This samples uses the pins 12 and 14. If you want to use the pin 26 and 10, then adjust the pinEcho and pinTrigger variables. This will then create a DHT22 sensor attached to pin 26 and start the measurement.

Please note that the few first measurements won't be correct, that's totally normal and related to the fact the sensor needs a bit of time to warm up and give data. Those sensors are very sensitive and too long wires, many perturbations, code compile as debug will increase the numbers of bad readings.

Result

dht22 output

Note: reading this sensor is sensitive, if you can't read anything, make sure you have it correctly cabled. Also note you'll get better results when running in Release mode.

Product Compatible and additional computed target framework versions.
.NET Framework net is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last updated
1.2.673 88 10/23/2024
1.2.662 81 10/11/2024
1.2.656 87 10/3/2024
1.2.639 117 9/6/2024
1.2.631 87 8/28/2024
1.2.613 105 8/9/2024
1.2.611 74 8/6/2024
1.2.601 75 7/26/2024
1.2.595 69 7/24/2024
1.2.590 86 7/17/2024
1.2.573 105 6/19/2024
1.2.570 82 6/14/2024
1.2.560 97 5/29/2024
1.2.548 94 5/15/2024
1.2.536 131 4/15/2024
1.2.514 127 3/22/2024
1.2.494 124 2/28/2024
1.2.474 151 1/24/2024
1.2.462 164 1/5/2024
1.2.458 148 12/20/2023
1.2.436 200 11/10/2023
1.2.416 144 11/8/2023
1.2.403 175 10/6/2023
1.2.396 156 9/27/2023
1.2.384 205 9/6/2023
1.2.378 188 8/16/2023
1.2.369 209 8/2/2023
1.2.363 173 7/28/2023
1.2.357 181 7/19/2023
1.2.354 179 7/14/2023
1.2.345 189 6/21/2023
1.2.341 178 6/14/2023
1.2.337 199 6/7/2023
1.2.335 188 6/2/2023
1.2.329 193 5/26/2023
1.2.316 198 5/16/2023
1.2.313 193 5/12/2023
1.2.302 190 5/10/2023
1.2.297 200 5/3/2023
1.2.273 332 3/17/2023
1.2.267 268 3/10/2023
1.2.263 277 3/8/2023
1.2.259 288 2/27/2023
1.2.256 304 2/24/2023
1.2.253 293 2/22/2023
1.2.235 310 2/13/2023
1.2.222 354 1/9/2023
1.2.217 347 1/6/2023
1.2.208 350 1/3/2023
1.2.203 342 12/28/2022
1.2.159 441 11/14/2022
1.2.153 403 11/5/2022
1.2.141 450 10/25/2022
1.2.128 443 10/22/2022
1.2.122 480 10/12/2022
1.2.114 466 10/8/2022
1.2.95 485 9/22/2022
1.2.87 524 9/15/2022
1.2.73 447 9/8/2022
1.2.63 483 9/3/2022
1.2.47 508 8/15/2022
1.2.40 479 8/6/2022
1.2.38 473 8/5/2022
1.2.28 465 8/1/2022
1.2.13 464 7/24/2022
1.2.10 469 7/23/2022
1.1.142.3202 509 7/7/2022
1.1.133.52556 489 6/30/2022
1.1.121.35854 498 6/26/2022
1.1.116.8772 460 6/24/2022
1.1.113.2032 474 6/23/2022
1.1.102.51394 454 6/15/2022
1.1.99.36719 463 6/14/2022
1.1.72.29765 488 5/31/2022
1.1.64.21380 497 5/26/2022
1.1.58.10097 487 5/23/2022
1.1.54.28879 482 5/23/2022
1.1.51.31918 494 5/20/2022
1.1.40 525 5/5/2022
1.1.3 503 4/15/2022
1.1.1 488 4/14/2022
1.0.300 493 3/31/2022
1.0.28-preview.114 131 3/25/2022
1.0.28-preview.113 119 3/25/2022
1.0.28-preview.103 114 3/21/2022
1.0.28-preview.100 116 3/19/2022
1.0.28-preview.99 127 3/18/2022
1.0.28-preview.98 111 3/18/2022
1.0.28-preview.94 130 3/15/2022
1.0.28-preview.93 119 3/15/2022
1.0.28-preview.86 132 3/8/2022
1.0.28-preview.77 128 2/27/2022
1.0.28-preview.75 117 2/26/2022
1.0.28-preview.65 129 2/18/2022
1.0.28-preview.63 116 2/16/2022
1.0.28-preview.61 123 2/12/2022
1.0.28-preview.58 119 2/10/2022
1.0.28-preview.53 122 2/9/2022
1.0.28-preview.48 145 2/4/2022
1.0.28-preview.42 140 1/31/2022
1.0.28-preview.41 138 1/31/2022
1.0.28-preview.29 133 1/28/2022
1.0.28-preview.22 127 1/27/2022
1.0.28-preview.20 134 1/27/2022
1.0.28-preview.19 130 1/27/2022
1.0.28-preview.18 131 1/27/2022
1.0.28-preview.5 134 1/24/2022
1.0.28-preview.3 129 1/21/2022
1.0.28-preview.1 129 1/21/2022
1.0.12 177 1/10/2022
1.0.2 360 12/23/2021
1.0.1 162 12/22/2021